Refrigerant systems
For applications suited to condensation-based moisture removal. Selection depends on entering air conditions and required humidity.
Dehumidification for data centers, warehouses and production facilities in Indonesia. Refrigerant or desiccant systems, selected and integrated around your humidity requirements.
Industrial and commercial dehumidification, from standing and duct-connected cabinets to our key DSD desiccant range. Moisture control built around your conditions, with engineering, installation and ongoing support. Selection starts with the application, not a model number.
For applications suited to condensation-based moisture removal. Selection depends on entering air conditions and required humidity.
For applications where low humidity or operating temperature makes a desiccant approach worth considering.
Standalone or duct-connected arrangements, coordinated with your air distribution, controls and site access.
Moisture removal by cooling air so water condenses. Selection depends on the operating temperature, humidity, moisture load and required airflow.
Define the cabinet format, duct interfaces and condensate drainage around your application. Final duty is confirmed at the project’s design conditions.
Explore equipment configurationsDiscuss refrigerant dehumidificationRotor-based moisture control. Explore the DSD range when the required conditions call for a desiccant approach, with selection based on the process and regeneration requirements.
Explore desiccant dehumidifiersFrom refrigerant and desiccant systems to duct-connected cabinets. Start with the environment, then define the equipment.

A cabinet format that makes duct connections, condensate drainage and service access part of the engineering conversation.
View refrigerant specifications
A floor-standing cabinet format for project-led humidity control. Confirm the selected technology, model, capacity and interfaces against your design conditions.
View refrigerant specifications
Rotor-based moisture control, with eleven DSD models for application-led selection. Explore the range and the design conditions that determine the right duty.
View DSD specifications
The cabinet is only one part of the brief. Air connections, drainage, electrical provision, control interfaces and the space to maintain the unit need to work together.
Eight standard DTD refrigerant models, with capacity and electrical data in one consistent format. Airflow and custom cabinet or ceiling configurations are specified for your project.
Compare models below. On smaller screens, scroll the table horizontally.
| Model | Moisture removal at 30°C / 80% RH | Airflow | Rated input | Details |
|---|---|---|---|---|
| DTD 6.8KT | 168 L/day | 1,800 m³/h | 2.5 kW | Full specifications for DTD 6.8KT |
| DTD 7.0KT | 168 L/day | 1,800 m³/h | 2.8 kW | Full specifications for DTD 7.0KT |
| DTD 8.0KT | 192 L/day | 1,800 m³/h | 3.5 kW | Full specifications for DTD 8.0KT |
| DTD 9.0KT | 216 L/day | 2,400 m³/h | 4.2 kW | Full specifications for DTD 9.0KT |
| DTD 10KT | 240 L/day | 2,800 m³/h | 4.5 kW | Full specifications for DTD 10KT |
| DTD 12KT | 288 L/day | 3,000 m³/h | 5 kW | Full specifications for DTD 12KT |
| DTD 20KT | 480 L/day | Specified with selection | 9 kW | Full specifications for DTD 20KT |
| DTD 25KT | 600 L/day | Specified with selection | 11 kW | Full specifications for DTD 25KT |
| Moisture removal | 168 L/day at 30°C / 80% RH |
|---|---|
| Airflow | 1,800 m³/h |
| External static pressure | > 80 Pa |
| Rated input | 2.5 kW |
| Rated current | 12 A |
| Power supply | 220V / 50Hz / 1Ph |
| Refrigerant | R410A |
| Operating temperature | 5–38°C |
| Weight | 122 kg |
| Moisture removal | 168 L/day at 30°C / 80% RH |
|---|---|
| Airflow | 1,800 m³/h |
| External static pressure | > 80 Pa |
| Rated input | 2.8 kW |
| Rated current | 5.6 A |
| Power supply | 380V / 50Hz / 3Ph |
| Refrigerant | R410A |
| Operating temperature | 5–38°C |
| Weight | 122 kg |
| Moisture removal | 192 L/day at 30°C / 80% RH |
|---|---|
| Airflow | 1,800 m³/h |
| External static pressure | > 80 Pa |
| Rated input | 3.5 kW |
| Rated current | 7 A |
| Power supply | 380V / 50Hz / 3Ph |
| Refrigerant | R410A |
| Operating temperature | 5–38°C |
| Weight | 130 kg |
| Moisture removal | 216 L/day at 30°C / 80% RH |
|---|---|
| Airflow | 2,400 m³/h |
| External static pressure | > 80 Pa |
| Rated input | 4.2 kW |
| Rated current | 8.4 A |
| Power supply | 380V / 50Hz / 3Ph |
| Refrigerant | R410A |
| Operating temperature | 5–38°C |
| Weight | 135 kg |
| Moisture removal | 240 L/day at 30°C / 80% RH |
|---|---|
| Airflow | 2,800 m³/h |
| External static pressure | > 150 Pa |
| Rated input | 4.5 kW |
| Rated current | 9 A |
| Power supply | 380V / 50Hz / 3Ph |
| Refrigerant | R407C |
| Operating temperature | 5–38°C |
| Weight | 140 kg |
| Moisture removal | 288 L/day at 30°C / 80% RH |
|---|---|
| Airflow | 3,000 m³/h |
| External static pressure | > 150 Pa |
| Rated input | 5 kW |
| Rated current | 10 A |
| Power supply | 380V / 50Hz / 3Ph |
| Refrigerant | R407C |
| Operating temperature | 5–38°C |
| Weight | 150 kg |
| Moisture removal | 480 L/day at 30°C / 80% RH |
|---|---|
| Airflow | Specified with selection |
| External static pressure | Specified with selection |
| Rated input | 9 kW |
| Rated current | 18 A |
| Power supply | 380V / 50Hz |
| Refrigerant | R407C |
| Operating temperature | 5–38°C |
| Weight | 230 kg |
Airflow, external static pressure and electrical phase are confirmed for the selected configuration.
Discuss DTD 20KT| Moisture removal | 600 L/day at 30°C / 80% RH |
|---|---|
| Airflow | Specified with selection |
| External static pressure | Specified with selection |
| Rated input | 11 kW |
| Rated current | 22 A |
| Power supply | 380V / 50Hz |
| Refrigerant | R407C |
| Operating temperature | 5–38°C |
| Weight | 240 kg |
Airflow, external static pressure and electrical phase are confirmed for the selected configuration.
Discuss DTD 25KTTimer on/off, defrost control, power-outage memory and compressor start-delay protection. Control options depend on the selected configuration.
Air distribution is selected around your installation. Air direction, duct connections, controls and cabinet dimensions are defined in the configuration-specific technical schedule.
Request a configuration-specific datasheetLooking for rotor-based moisture control?
Compare all 11 DSD desiccant models
Equipment, ductwork, controls, drainage and service access. Good integration considers them together.
Explore our delivery approachEquipment configuration is developed from the agreed design basis. We confirm model data and installation interfaces before supply.
Discuss your projectOwners, consultants and contractors can define supply responsibilities, installation interfaces and the agreed testing and handover requirements with Drytronics.
Discuss the operating conditions and site constraints before finalizing equipment. Explore the relevant industry context below.
Discuss your applicationDefine humidity targets, outside-air loads and system interfaces.
Review stored materials, room volume, door openings and infiltration.
Coordinate process moisture, air handling and cleaning requirements.
Assess the conditions needed by sensitive materials and collections.
Required temperature, relative humidity or dew point, including acceptable operating ranges.
Room volume, outdoor air, infiltration, people and process-related moisture sources.
Duct routes, power, drainage, access clearances and control interfaces.
Hours of operation, redundancy requirements and maintenance arrangements.
Model capacities, dimensions, electrical characteristics and performance data are confirmed against selected equipment and design conditions.
Industrial dehumidifier supply and integration for DCI facilities across three locations.
Start with the required temperature and relative humidity or dew point, then assess moisture from outdoor air, infiltration, people and processes. Capacity is reviewed at the actual design conditions, not only a catalog rating.
An existing-system assessment can establish the duct route, power supply, drainage, controls and service access. Supply and installation responsibilities are agreed with the owner, consultant or contractor.
Yes, subject to technical assessment, service information and parts availability. Share the brand, model, site conditions, symptoms and service history to define the work.