Define the cooling duty
Review the design load, chilled-water temperatures, flow and operating schedule.
Air-cooled scroll water chillers for industrial and commercial chilled-water systems in Indonesia. Explore the DRCH series, with 172 kW and 232 kW nominal cooling duties.
Nominal ratings apply at the stated ambient and water conditions.
Cooling-only chilled-water equipment, selected around the required load, water temperatures and operating conditions. Selection starts with the application, not a model number.
Review the design load, chilled-water temperatures, flow and operating schedule.
Consider structural loads, condenser airflow, hydraulic interfaces and service access.
Agree the control strategy, RS485 / Modbus RTU interface and commissioning responsibilities.
Air-cooled scroll chillers for chilled-water systems. Start with the required water temperature, cooling load and site conditions.

Ambient: 35°C dry bulb / 24°C wet bulb. Chilled water: 12°C inlet / 7°C outlet. Capacity, input power and EER apply at these rated conditions.
Confirm the final approved datasheet, arrangement drawing and site interfaces before specification or ordering.
Allow for operating weight, structural support, service access, condenser airflow and hydraulic design. Pumps, buffer tanks, electrical protection and commissioning scope are defined separately for the project.
The DRCH series is cooling-only. Listed capacity depends on the stated rating conditions; final selection and system components are confirmed for the project.
Discuss your projectOwners, consultants and contractors can define supply responsibilities, installation interfaces and the agreed testing and handover requirements with Drytronics.
Discuss the operating conditions and site constraints before finalizing equipment. Explore the relevant industry context below.
Discuss your applicationReview the required cooling duty, temperatures and operating profile.
Coordinate cooling with air-handling and filtration requirements.
Review the building load, available space and existing mechanical systems.
Consider cooling, humidity and air distribution together.
Required duty, load variation, design water temperatures and operating schedule.
Flow, pipework, pump selection, available pressure, water quality and system volume.
Design ambient, plant location, operating weight, structural support and clear airflow.
Electrical supply, integration, acceptance criteria, installation and commissioning scope.
Model capacities, dimensions, electrical characteristics and performance data are confirmed against selected equipment and design conditions.
HVAC design-build for PT Ultrajaya Milk Industry Tbk at its Cikarang MM2100 facility.
These are air-cooled scroll water chillers. They produce chilled water for a connected system; they are not direct room-air coolers.
No. These are nominal catalog ratings at 35°C dry-bulb / 24°C wet-bulb ambient and 12°C inlet / 7°C outlet water. Selection must be checked against your actual design conditions.
Pump and buffer-tank provision is confirmed in the selected configuration and agreed project scope.